Recoton/Advent U31-LP2 Stove User Manual


 
23
FPI U31-2 Gas Fireplace Insert
Top View of pilot fl ame
Correct fl ame pattern has two strong blue
ames: 1 fl owing around the thermopile and
1 reaching towards the rear burner (it does
not have to be touching the burner).
Top View of pilot fl ame
Incorrect fl ame pattern will have small, prob-
ably yellow fl ames, not coming into proper
contact with the rear burner or thermopile.
MAINTENANCE
INSTRUCTIONS
1) Always turn the gas valve to off before
cleaning. For relighting, refer to lighting
instructions. Keep the burner and control
compartment clean by brushing and vacu-
uming at least once a year.
When cleaning the logs, use a clean soft
paint brush as the logs are fragile and easily
damaged.
2) Clean (never when unit is hot) appliance,
door and louvers with a damp cloth. Never
use an abrasive cleaner. The gold louvers
(and optional gold door) may be scratched
if abrasives are used to clean them.
The heater is fi nished in a heat resistant
paint and should only be refi nished with
heat resistant paint (not with wall paint).
FPI uses StoveBrite Paint - Metallic Black
#6309.
3) Make a periodic check of burner for proper
position and condition. Visually check the
ame of the burner periodically, making sure
the fl ames are steady; not lifting or fl oating.
If there is a problem, call a qualifi ed service
person.
4) The appliance and venting system must be
inspected before use, and at least annually,
by a qualifi ed fi eld service person, to ensure
that the fl ow of combustion and ventilation
air is not obstructed.
During the annual service call, the burners
should be removed from the burner tray
and cleaned. Replace the embers but do
not block the pilot.
MAINTENANCE
WARNING: CHILDREN AND
ADULTS SHOULD BE ALERTED
TO THE HAZARDS OF HIGH
SURFACE TEMPERATURE AND
SHOULD STAY AWAY TO AVOID
BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM
AS THE APPLIANCE.
CAUTION: ANY SAFETY SCREEN
OR GUARD REMOVED FOR SERV-
ICING AN APPLIANCE MUST BE
REPLACED PRIOR TO OPERAT-
ING THE APPLIANCE.
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT
BE PLACED ON OR NEAR THE
APPLIANCE.
GOLD-PLATED TRIM
The 24 carat gold plated fi nish on the trim
requires little maintenance, and need only be
cleaned with a damp cloth. DO NOT use abrasive
materials or chemical cleaners, as they may
harm the fi nish and void the warranty.
Clean any fi ngerprints off before turning the
unit on. If the top louvers start to discolour,
check the door gasket seal and replace if
necessary.
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door to carefully remove the
logs. The pilot light generates enough heat to
burn someone. If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagram under Log
Installation.
NOTE: Improper positioning of logs may
create carbon build-up and will alter
the unit’s performance which is not
covered under warranty.
GLASS GASKET
If the glass gasket requires replacement use
7/8" fl at glass gasket (Part # 936-243) for the
Bay Front and for the Flush Front.
are temperature changes within the unit these
sounds will likely re-occur. Again, this is normal
for steel fi reboxes.
Blower Thermodisc:
When this thermally activated switch turns ON
it will create a small "clicking" sound. This is the
switch contacts closing and is normal.
Pilot Flame:
While the pilot fl ame is on it can make a very
slight "whisper" sound.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.
5) Keep the area near the appliance clear and
free from combustible materials, gasoline
and other fl ammable vapours and liquids.
6) Each time the appliance is lit, it may cause
condensation and fog the glass. This
condensation and fog is normal and will
disappear in a few minutes as the glass
heats up.
Never operate the appliance without the
glass properly secured in place, with
broken glass or with the door open.
7) Verify proper operation after servicing.
8) Periodically check the pilot fl ames, there
should be three strong blue fl ames approx.
3/4" long - 1 fl ame to the front burner, and
1 to the thermopile and one to the left. See
diagrams below.
If you have an incorrect fl ame pattern,
contact your FPI dealer for further instruc-
tions.