Quadra-Fire 31M-ACC-GT Stove User Manual


 
Page 36
7033-277C
March 2, 2007
R
3100 Wood Stove Series (ACC)
10
Troubleshooting
With proper installation, operation, and maintenance your woodstove
will provide years of trouble-free service. If you do experience a prob-
lem, this troubleshooting guide will assist a quali ed service person in
the diagnosis of a problem and the corrective action to be taken.
Diagnostic Question Possible Causes of Condition Solutions
Are the air controls open? No draft
No combustion air
Open air controls
Is there enough paper? Insuf cient heat to ignite kindling Use more paper
Is there enough kindling?
Is the kindling dry?
Insuf cient heat to ignite fuel Use drier kindling
Is there enough or too much wood?
Is it too large?
Is it dry enough?
• Insuf cient heat to establish draft
• Insuf cient air passage
• Insuf cient surface area
Ignition temperature high due to
moisture
Use small split wood that is well sea-
soned (split, covered on top minimum 6
months, preferably a year)
Are there adequate air spaces
between fuel pieces?
Insuf cient combustion air and
exposed surface area
Arrange kindling and wood for air move-
ment
Is the chimney pre-warmed? Exposed, cold chimney downdrafting Use lighted rolled newspaper at ue
opening to start upward air movement
Is there smoke in the house? Obstruction in chimney
Downdraft from chimney tem-
perature or from negative house
pressure
Have chimney checked if it workd
previously
• Pre-warm chimney
Shut off exhaust devices
Open window slightly
Does the kindling wood not ignite? Condition, amount, arrangement of
kindling and fuel
Use more, drier, well-spaced kindling
and fuel.
Does the kindling ignite, but the fuel
doesn’t?
Amount of kindling
Condition of fuel
• Use more kindling
Use smaller, dry wood
Does the fuel ignite, but not burn well? Draft problem
Condition of fuel
Use well-seasoned wood and suf-
cient amount
Turn exhaust fans off
Open window slightly
1. If I can’t get a good re going, what am I doing wrong?
2. I smell smoke in the house after we have had a re. What is the cause/what can I do?
Diagnostic Question Possible Causes of Condition Solutions
Is the chimney clean? No: Creosote odor Have chimney cleaned
3. I smell smoke in the house during operation. What is causing it?
Diagnostic Question Possible Causes of Condition Solutions
Do res start and burn well? No:
• Chimney obstruction
Not enough kindling and/or fuel to
establish draft
Inadequate combustion air
Air controls not open
Yes:
Competition with exhaust devices
No:
Check & clean chimney if needed
Use adequate kindling & fuel
Open air controls
• Open window
Check for need for balanced air
make-up (Outside Air)
Yes:
Do not use exhaust fans during
startup
Check for need for balanced air
make-up (Outside Air)