Pfaff 583 Sewing Machine User Manual


 
Adjustment
22
Fig. 1 - 16
1.06.16 Tension release mechanism
Requirement
When presser bar lifter 3 is raised both tension discs must be at least 0.5 mm apart.
Adjust tension release lever 1 (screw 2) according to the requirement.
Lower the presser foot onto the needle plate. Now the tension must be fully activated.
2
3
1
0,5 mm