Problem Cause Solution
Solution Tank Water source turned off Turn on faucet or find other water source
not filling Float not on valve arm Reconnect float to valve arm - Adjust to proper height/level
Float valve faulty Repair or replace float valve
Water hose restricted Un-kink, clean out or replace hose
Quick connects faulty Clean out or replace quick connects
Solution tank Float too heavy/ Filled with water Replace float
overflowing Float & chain tangled Make sure float chain free & hanging properly
Float too high Adjust chain to set float at proper level
Float valve faulty Repair or replace float valve
*
To reduce the risk of fire electrical shock or injury repairs to wiring should only be performed by
experienced service technicians.
If you are not experienced in checking electrical wiring contact your nearest authorized service
center to perform tests and repairs to wiring and switches.
Contact your distributor for additional troubleshooting
assistance, to order parts, or for advice and assistance in
performing necessary repairs.