Napoleon Fireplaces GDI30 Indoor Fireplace User Manual


 
7
W415-0806 / 06.28.09
64.5%
GDI-30
1.5 GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
MINIMUM INLET: Gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for
propane.
MAXIMUM INLET: Gas pressure is 7 inches water column for natural gas and 13 inches water column for propane.
Manifold pressure under ow conditions is 3.5 inches water column for natural gas and 10 inches water column for
propane.
When the appliance is installed at elevations above 4,500ft, and in the absence of speci c recommendations from
the local authority having jurisdiction, the certi ed high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft. Expansion / contraction noises during heating up and cooling down cycles are normal and to be
expected.
MAXIMUM INPUT: Is 24,500 BTU/hr for natural gas and propane.
MAXIMUM OUTPUT: For natural gas and propane is 20,825 BTU/hr at an ef-
ciency of 85% with the fan on. The maximum A.F.U.E. (annual fuel utilization
ef ciency) rating is 82%.
This appliance insert is not approved for closet or recessed installations. It is
approved for bathroom, bedroom and bed-sitting room installations and is suit-
able for mobile homes. The natural gas model is suitable for installation in a
mobile home that is permanently positioned on its site and fuelled with natural
gas.
1.6 CARE OF GLASS
5.1
DO NOT CLEAN GLASS WHEN HOT! DO NOT USE
ABRASIVE CLEANERS TO CLEAN GLASS.
Buff lightly with a clean dry soft cloth. Clean the glass after
the rst 10 hours of operation with a recommended replace
glass cleaner. Thereafter clean as required. If the glass is not
kept clean permanent discoloration and / or blemishes may
result.
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
!
WARNING