5.0 OPTIONAL BLOWER INSTALLATION
FIGURE 8
FRONT BLOWER ACCESS COVER
THERMODISC / BRACKET
ASSEMBLY
REAR BLOWER ACCESS COVER
5.0.1 Turn off the electrical power and the gas supply to the appli-
ance insert.
5.0.2 Open the glass door and remove the logs and bre bricks, if
installed.
5.0.3 Remove the front blower access cover held on with 4
screws.
5.0.4 Remove the rear blower access cover. NOTE: Check the
blower gasket for damage. Replace if damaged.
5.0.5 Disconnect the two blower wires. Remove the blower
from the mounting plate and replace. For thermodisc
replacement: Remove the mounting bracket secured
to the underside of the burner base. Remove the
thermodisc from the bracket and replace.
5.0.6 Reconnect the two wires. Re-install the blower gas-
ket. Reattach the blower mounting plate and blower
access covers. Replace the logs. Close the re view-
ing door.
5.0.7 Turn the gas supply and electricity back on. Because
the blower is thermally activated, when turned on, it
will automatically start approximately 5-15 minutes
after lighting the appliance insert and will run for ap-
proximately 30-45 minutes after the appliance insert
has been turned off. Use of the fan increases
the output of heat.
Drywall dust will penetrate into the blower bear-
ings causing irreparable damage and must be
prevented from coming into contact with the
blower or its compartment. Any damage result-
ing from this condition is not covered by the
warranty policy.
!
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS
COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL
VOID THE WARRANTY AND CERTIFICATION.
ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE
APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER
CORD BENEATH THE APPLIANCE.