4.0 FINISHING
The upper louvres must be removed to allow the door
to be opened or closed. To access the lower door latch,
open the valve control door. Release the top and bottom
door latches, located at the right side of the door.
NOTE: The protective wrap on plated parts is best
removed when the assembly is at room temperature
but this can be improved if the assembly is warmed,
using a hair dryer or similar heat source.
4.1 DOOR REMOVAL AND INSTALLATION
DOOR LATCH
4.2 DOOR GLASS REPLACEMENT
56.1
Place the door frame face down careful not to scratch the
paint.
Center the gasketed glass inside the door frame with the thick
side of the gasket facing up.
Bend the glass retainers located along the edge of the door
frame over the gasket holding the glass in place. Careful not
to break the glass.
GLASS
GASKET
DOOR
FRAME
GLASS
RETAINER
!
WARNING
DO NOT USE SUBSTITUTE MATERIALS.
GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.
CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN GLASS OR
DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE
APPLIANCE BEFORE OPERATION.
DO NOT OPERATE THE APPLIANCE WITH THE GLASS DOOR REMOVED, CRACKED OR BROKEN.
NOTE: Care must be taken when removing and disposing of any broken glass or damaged compo-
nents. Be sure to vacuum up any broken glass from inside the appliance before operation.