7.0 ADJUSTMENTS
7.1 PILOT BURNER ADJUSTMENT
Adjust the pilot screw to provide properly sized ame. Turn in a clockwise
direction to reduce the gas ow.
Inlet pressure can be checked by turning screw (A) counter-
clockwise until loosened and then placing pressure gauge
tubing over the test point. Gauge should read 7” (minimum 4.5”)
water column for natural gas or 13” (11” minimum) water column for
propane. Check that main burner is operating on “HI”.
Outlet pressure can be checked the same as above using screw (B).
Gauge should read 3.5” water column for natural gas or 10” water column
for propane. Check that main burner is operating on “HI”.
AFTER TAKING PRESSURE READINGS, TIGHTEN SCREWS FIRMLY
TO SEAL. DO NOT OVER TORQUE. LEAK TEST.
39.3
P
I
P
I
L
O
T
N
O
L
O
T
H
I
L
O
F
F
O
PILOT
BURNER
THERMOCOUPLE
THERMOPILE
7.2 VENTURI ADJUSTMENT
This appliance has an air shutter that has been
f
actory set open according to the chart below:
Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will
cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow
immediately; allow 15 to 30 minutes for the final flame color to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
AIR SHUTTER
OPENING
VENTURI
ORIFICE
49.2
GDI-30
NG 1/4”