Napoleon Fireplaces Fireplace Indoor Fireplace User Manual


 
6
W415-0619 / B / 03.03.08
For safe and proper operation of the replace follow the venting instruction exactly.
Deviation from the minimum or the maximum vertical vent length can create dif culty in burner start-up and/or carboning.
Under extreme vent con gurations, allow several minutes (5-15) for the ame to stabilize after ignition.
Vent lengths that pass through unheated spaces (attics, garages, crawl spaces) should be insulated with the insulation
wrapped in a protective sleeve to minimize condensation.
Provide a means for visually checking the vent connection to the replace after the replace is installed.
Use restop spacer (W500-0358) when penetrating interior walls and ceilings.
VENT INSTALLATIONS
HORIZONTAL VENT SECTIONS
A minimum clearance of 1" at the bottom, sides and top of the vent pipe in all horizontal runs to combustibles is
required. Use restop spacer W500-0358 (supplied).
VERTICAL VENT SECTIONS
A minimum of 1" all around the vent pipe on all vertical runs to combustibles is required. Use restop spacer
W500-0358 (not supplied).