A. This fi replace is equipped with a pilot which must be
lit by hand while following these instructions exactly.
B. Before operating smell all around the fi replace area
for gas and next to the fl oor because some gas is
heavier than air and will settle on the fl oor.
C. Use only your hand to turn the gas control knob /
manual shut-off knob. Never use tools. If the knob
will not turn by hand, do not try to repair it. Call a
qualifi ed service technician. Force or attempted re
pair may result in a fi re or explosion.
D. Do not use this fi replace if any part has been under
water. Immediately call a qualifi ed service technician
to inspect the fi replace and replace any part of the
control system and any gas control which has been
under water.
When lit for the fi rst time, the fi replace will emit a slight odor for a few hours. This is a normal temporary condition caused by the curing
of the paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to suffi ciently ventilate
the room.
After extended periods of non-operation such as following a vacation or a warm weather season, the fi replace may emit a slight odor for
a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to suffi ciently ventilate the room.
Purge all gas lines with the glass door of the fi replace removed. Assure that a continuous gas fl ow is at the burner before
installing the door.
Do not touch any electric switch.
Do not use any phone in your building.
If you cannot reach your gas supplier, call the fi re
department.
Turn off all gas to the fi replace.
Do not try to light any appliance.
Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
WARNING: if you do not follow these
instructions exactly, a fi re or explosion may
result causing property damage, personal
injury or loss of life. Initial lighting of the pilot
and main burners must be done with the
glass door off.
8. This unit is equipped with an auto-spark.
Depress and hold gas knob . Keep knob fully
depressed for one minute, then release. If pilot does not
continue to burn repeat steps 3 through 7.
9. With pilot lit, push and turn gas knob counter-clock
wise
to on.
10. If equipped with fl ame adjustment valve, turn knob to
high.
11. If equipped with remote on-off switch, main burner may not
come on when you turn the valve to on or high. Remote
switch must be in the on position to ignite burner.
12. Turn on all electric power to the fi replace.
OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE
LIGHTING:
LIGHTING INSTRUCTIONS
TO TURN OFF GAS
WHAT TO DO IF YOU SMELL GAS
FIGURE 65
GAS KNOB
P
I
L
O
T
O
N
F
F
O
FIGURE 66
3. For a temporary shut-down procedure: set the switch to off.
Press and turn the gas knob clockwise
to pilot.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE
SERVICING THE FIREPLACE.
1. Turn off all electric power to the fi replace if service is to be
performed.
2. For a complete shut-down procedure: push in gas control knob
slightly and turn clockwise
to off. Do not force.
Do not connect valve or wall switch to electricity. See installation
instructions.
When lighting and re-lighting, the gas knob cannot be turned from
pilot to off unless the knob it depressed slightly.
1. STOP! Read the safety information on the operating label.
2. Turn off all electric power to the fi replace.
3. Turn the gas knob clockwise
to off.
4. Wait 5 minutes to clear out any gas. If you smell gas,
including near the fl oor, STOP! Follow “B” on the operating
label. If you don’t smell gas, go to the next step.
5. If the fi replace is equipped with a fl ame adjustment
valve, turn clockwise to off.
6. Find pilot located in front of the back log on the right.
7. Turn gas knob counter-clockwise to pilot.