Use only non-combustible material such as
cement board, ceramic tile, marble, etc. when
finishing to the fireplace. DO NOT USE
WOOD OR DRYWALL.
!
WARNING
FIGURE 29
MINIMUM CLEARANCE TO COMBUSTIBLES
Maintain these minimum clearances to combustibles from
fi replace and vent surfaces:
Fireplace framing:
- 0” to stand-offs
Combustible Fireplace fi nishing:
- 0” to rear
- 29 1/2” recessed depth
- 84” from bottom of unit to enclosure top
- 2” to top, sides, and bottom of vent pipe*
- 84” from bottom of unit to ceiling
Non- Combustible Fireplace fi nishing:
Front - 5 1/2” to sides of fi replace opening
- 23 3/4” to top of fi replace opening
* See Venting Section
It is recommended that the walls of the fi replace enclosure be fi nished.
This would ensure that clearance to combustibles is maintained
within the cavity.
Non-combustible fi nishing material (i.e. cement board, brick, stone,
tile) must be used to fi nish the front of the unit.
!
WARNING
Facing and/or fi nishing material must never overhang into the fi replace opening.