LS600 PUMP — START-UP PROCEDURE
DO NOT attempt to operate this concrete pump until
the Safety, General Information and Inspection
sections have been read and understood.
STARTING PROCEDURE
WARNING - GENERAL SAFETY GUIDELINES
1. Locate the Emergency Stop Switch (Figure 19) on the
Hydraulic Pump Control Box. Turn the Emergency Stop
switch clockwise and release (open). This will allow
the engine to start.
2. Turn the
Cylinder Stroke Control Switch
to the
AUTOMATIC position (Figure 20).
3. Place the
Pumping Control Switch
to the CENTER
OFF position (Figure 21) for normal pumping operation.
Figure 19. Emergency Stop Switch
E
m
e
r
g
e
n
c
y
S
t
o
p
If the Emergency Stop switch is in the
CLOSED position (stop), engine will not
start. To start the engine, make sure the
Emergency Stop switch is in the OPEN
position (fully extended).
Figure 20. Cylinder Stroke
Control Switch (Automatic)
AUTOMATIC JOG
LOCAL
REMOTE
CENTER
OFF
Figure 21. Pumping Control Switch (OFF)
4. Place the
Direction Control Switch
to the FORWARD
position (Figure 22).
5. To start the engine, insert the key (Figure 23) into the
ignition switch and turn the key to the ON position.
6. When the ignition key is in the ON position, the Digital
Readout Screen (primary) will cycle through 3 displays
as shown in Figure 24.
7. Turn the key to the START position and listen for the
engine to start. In warm weather let engine warm up
for 5 minutes. In cold weather let engine warm up for
10 minutes.
FORWARD REVERSE
Figure 22. Direction Control Switch
(FORWARD)
Figure 23. Ignition Switch
Figure 24. Primary Screen (Ignition Key ON)