Monessen Hearth PL20 Indoor Fireplace User Manual


 
8

Parlor Vent Free Fireplace

This heater shall not be installed in a confined space or unusually tight construction unless
provisions are provided for adequate combustion and ventilation air.
 defines a confined space as a space
whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8 m
3
per kw) of the aggre-
gate input rating of all appliances installed in that space, and an unconfined space as a space
whose volume is not less than 50 cubic feet per 1,000 BTU per hour (4.8 m
3
per kw) of the
aggregate input rating of all appliances installed in that space. Rooms communicating directly
with the space in which the appliances are installed, through openings not furnished with doors,
are considered a part of the unconfined space.


a) walls and ceilings exposed to the outside atmosphere have a continuous water vapor
retarder with a rating of 1 perm
(6 x 10
11
kg per pa/sec-m
) or less with openings gasketed or sealed;
b) weather striping has been added on openable windows and doors, and
c) caulking or sealants are applied to areas such as joints around window and door frames,
between sole plates and floors, between wall-ceiling joints, between wall panels, at pen-
etrations for plumbing, electrical, and gas lines, and at other openings.
The following formula can be used to determine the maximum heater rating per the definition
of unconfined space:
(L1 + L) Ft x (W) Ft x (H) Ft
50
Consider two connecting rooms with an open area between, with the following dimensions:
L1 = 15Z\x Ft., L = 1 Ft., W = 1 Ft., H = 8 Ft.
(15Z\x + 1) x (1) x (8)
50
If there were a door between the two rooms the calculation would be based only on the room
with the heater.
(15Z\x) x (1) x (8)
50
x 1000
x 1000 = 5800 BTU/hr
x 1000 = 9,760 BTU/hr
BTU/hr =
BTU/hr =
BTU/hr =

W
H
FP2439
combustion air
Room Divider
Fireplace
Figure 3 -
Example of a Large Room with a Room
Divider
FP439

        
      
     
    


    
