Parlor Vent Free Fireplace

When tightening the joint to the valve, hold the valve securely to prevent movement.
Test all gas joints from the gas meter to the heater valve for leaks using a gas analyzer or
soap and water solution after completing connection. 
Check the gas pressure with the appliance burning and the control set to .
Open control access door at bottom front of unit to find valve and regulator referred to
below.










The valve regulator controls the burner pressure which should be checked at the pressure
test point.
Turn captured screw counter clockwise two or three turns and then place tubing to pres-
sure gauge over test point. (Use test point “A” closest to gas inlet). After taking pressure
reading, be sure and turn captured screw clockwise firmly to reseal. Do not over torque.
Check for gas leaks.
FP2511
millivolt test point
Test Port
'A'
FP511
Figure 14 -
Pressure Test Point Location - Millivolt Valve