1
Parlor Vent Free Fireplace
FP2273
pilot bad flame
FP2272
pilot correct flame
In addition, periodically check the flames visually during operation.
It should just
touch the top of the thermocouple tip for natural. for correct pilot flame.
If the pilot flame does not touch the thermocouple, then the main burner cannot function
reliably. for incorrect shape of pilot flame.
Figure 23 -
Millivolt Control Pilot Flame Appearance
Thermocouple
for Natural Gas
Thermocouple
for LP
FP7
Thermocouple
for Natural Gas
Thermocouple
for LP
FP73
In normal operation, at full rate after 15
minutes, the flames should appear as shown
in .
The flames should be yellow and extend 3-4"
above the log top surfaces. The yellow flames
should not impinge on the logs.
LG723
PL20 log flames
Figure 24 -
Correct Burner Flame Appearance
LG73