Monessen Hearth PL20 Indoor Fireplace User Manual


 
10

Parlor Vent Free Fireplace


Ensure that minimum clearances shown in are maintained. Left and right clearances
are determined when facing the front of the firebox.
Follow these instructions carefully to ensure safe installation. Failure to follow these requirements
may create a fire hazard.
 — The clearance from the inside of the appliance to any combustible adjacent
wall should not be less than 9". 
— The ceiling or any other combustible material must be at least 0" from the
firebrick opening. 
— The appliance may be placed against a combustible back wall.
— The fireplace may be installed directly on a combustible floor or a raised platform
of an appropriate height. Do not place fireplace on carpeting, vinyl, tile or other soft floor coverings.
It may, however, be placed on flat wood, plywood, particle board or other hard surfaces. Be sure
fireplace rests on a solid continuous floor or platform with appropriate framing for support and so
that no cold air can enter from under the firebox.
— Must meet the clearance requirements detailed in 

   Figures 5 and 6   




9” (229 mm)
Min.
FP2556
wall clg clear
20” (508 mm)
Min.
FP556
Figure 5 -
Sidewall and Ceiling Clearances
Sidewall
Ceiling, Shelving or Any
Combustible Material
20”
(508 mm)
Min.
FP2557
mantel clearance
Top of Fireplace
Opening
FP557
Figure 6 -
Mantel Clearances
45°
1”
4”
9”
FP2564
side leg clear
Fireplace
Opening
Wall
Combustible
Material Area
FP564


Wall
Combustible
Material