Mitsubishi Electronics PUZ-A42NHA2-BS Air Conditioner User Manual


 
81
SW2 setting
Display detail
Explanation for display Unit
1
ON
23456
%
Capacity save
0~100
When air conditioner is connected to
M-NET and capacity save mode is
demanded, “0”~”100” is displayed.
When there is no setting
of capacity save “100” is
displayed.
0~100
(When the capacity is 100%, hundreds digit, tens
digit and ones digit are displayed by turns.)
(Example) When 100%;
0.5 secs. 0.5secs. 2 secs.
Code
display
Error postponement code history (2)
of outdoor unit
Postponement code display
Blinking: During postponement
Lighting: Cancellation of postponement
“00” is displayed in case of no postponement.
Code
display
Error postponement code history (3)
of outdoor unit
Postponement code display
Blinking: During postponement
Lighting: Cancellation of postponement
“00” is displayed in case of no postponement.
Code
display
Error code history (3) (Oldest)
Alternate display of abnormal unit num-
ber and code.
When no error history, “0” and “– –“ are displayed by
turns.
Error thermistor display
When there is no error thermistor,
“–“ is displayed.
3: Outdoor pipe temperature /Liquid (TH3)
6: Outdoor pipe temperature /Cond./Eva. (TH6)
7: Outdoor outside temperature (TH7)
8: Outdoor heatsink (TH8)
1
ON
23456
1
ON
23456
1
ON
23456
1
ON
23456
Code
display
Operation frequency on error occurring
0~255
0~255
(When it is 100Hz or more, hundreds digit, tens digit
and ones digit are displayed by turns.)
(Example) When 125Hz;
0.5 secs. 0.5secs. 2 secs.
1
ON
23456
Hz
Fan step on error occurring
0~10
0~10
1
ON
23456
Step
00
1
25
1
OCH429--3.qxp 07.11.20 9:19 AM Page 81