Mitsubishi Electronics PCA-A24GA Air Conditioner User Manual


 
21
10-4. WHEN WIRED REMOTE CONTROLLER OR INDOOR UNIT
MICROCOMPUTER TROUBLES
1. If there is not any other problem when trouble occurs, emergency operation starts as the indoor controller board switch
(SWE) is set to ON.
During the emergency operation the indoor unit operates with Indoor fan at high speed.
2. For emergency operation of cooling or heating
In emergency operation for COOL or HEAT, setting of the switch (SWE) in the indoor controller board and outdoor unit
emergency operation are necessary.
3. Before you activate emergency operation, check the following points:
(1) Emergency operation cannot be activated when:
· the outdoor unit malfunctions.
· the indoor fan malfunctions.
(2) Emergency operation becomes continuous only by switching the power source on / off. ON / OFF on the remote control
or temperature control etc. does not function.
(3) Avoid operating for a long time when the outdoor unit begins defrosting while emergency operation of the heating is acti-
vated, because it will start to blow cold air.
(4) Emergency cooling should be limited to 10 hours maximum. (The indoor unit heat exchanger may freeze.)
(5) After emergency operation has been deactivated, set the switches etc. to their original positions.
(6) Movement of the vanes does not work in emergency operation, therefore you have to slowly set them manually to the
appropriate position.
OC368B--1.qxp 07.6.20 1:01 PM Page 21