Mitsubishi Electronics A172SHCPUN Home Security System User Manual


 
1. SPECIFICATIONS OF MOTION SYSTEM COMPONENTS
1
22
(7) Information control processing making use of personal computer
By connecting a personal computer to the SSCNET, you can add to the motion
system the digital oscilloscope functions used for monitoring the equipment
status and for checking the operation, tuning and timing of the equipment and
the user-developed software functions (e.g. machining/assembling recipe
function and data supervising collection function).
Refer to the manual of the corresponding software package.
CPU module
SSCNET connector
SSCNET cable
Communication cable
(A270CDCBL M/A270BDCBL M)
Panel computer, etc.
SSC I/F card/board
(
A30CD-PCF/A30BD-PCF
)
*
* : Connect to SSCNET2 for the A171SHCPUN/A172SHCPUN or to
SSCNET4 for the A173UHCPU.
(8) MELSECNET(II)/10 system
The motion system can use the MELSECNET(II)/10 system. The usable
MELSECNET system depends on the CPU module. (See the following table.)
Load the module given in the following table into the PC slot to configure a data link
system.
MELSECNET
System
A172SHCPUN/A171SHCPUN A173UHCPU Module
MELSECNET (II)
Usable(MELSECNET mode or
MELSECNET II mixed mode
only)
Usable A1SJ71AP21/R21
MELSECNET/10 Usable (local station only) Usable
A1SJ71LP21/BR11
In the MELSECNET(II) data link system, the motion CPU module can be used
as the master or local station in each layer. When it is used as the master
station in layer 3 (local station in layer 2), up to two data link modules
(A1SJAP21/R21) may be used.
In the MELSECNET/10 network system, the motion CPU module can be used
as the control or normal station. Up to four network modules
(A1SJ71LP21/BR11) may be loaded to achieve separate network
configurations.
Refer to the following manuals when using the MELSECNET(II) data link system
and MELSECNET/10 network system.
MELSECNET(II), MELSECNET/B data link system reference manual
MELSECNET/10 data link system reference manual (Inter-PC network
manual)