Specifications
Table 6 indicates the operational limitations of the MAYTAG Whole Home Water Filtration
System.
Table 6 – Operational Limits of the System
Pressure Drop at 34 LPM (kPa/psi)*
MWF4100AWS …………………………………………………. 17/4.5
MWF4200AWS MWF 4300AWS
………………………………… 34/9
Minimum height required (m/in.)……………………………… 1.88/74
Base Width (m/in.)………………………………………………. 0.45x0.45/18x18
Controller Voltage………………………………………………. 120V
System Efficiency…………………………………………….. 97%
Approx flush volume (L/USgal)……………………………… 45/12
Maximum Temp (C/F)………………………………………… <38/100
Minimum Temp (C/F)………………………………………… >0/32
Rated Capacity (L/USgal per day)**………………………… 1500/390
MWF4100AWS ………………………………………………… 17/2.5
MWF 4200AWS MWF4300AWS ……………………………… 41/6
Recommended Max Flow Rate Per/min (LPM/USgpm)
*At time of installation
** Depends on water quality and flow rate
Maximum working pressure (kPa/psi)……………………… 690/100