Advanced Controller setup procedure
Advanced Controller
Use with waters
having turbidity up
to 5.0NTU,
Has two output
terminals and
controls the
automated drain
and inlet valve.
1. Modes: Use ‘next’ button to toggle through modes.
2. Manual flush: Press ‘next’ until ‘manual’ is flashing. Press ’manual flush’
and hold. If held for longer than 10 seconds, drain valve remains open. Toggle
drain valve closed by pressing ‘manual flush’ once.
3. Setting time of day: Press ‘next’ until ‘set time’ appears. Press ‘enter’. Use
up/down arrows to set time of day. Press ‘enter’ to set.
4. Set time of flush: Press ‘next’ until ‘start time’ appears. Press ‘enter’. Use
up/down arrows to set time of flush. Press ‘enter’ to set.
5. Setting program choice: Press ‘next’ until ‘program’ appears. Press ‘enter’.
Use up/down arrows to select program choice. Press ‘enter’ to set.
(See Table 6 for programming choices.)
Table 4-Advanced Controller Setup Procedure
Choosing a Controller Program
Base Controller
Controller-
Program
Recommended
household
occupancy
(persons)
Source water
turbidity
(NTU)
Daily household
water consumption
No.
Flushes
per cycle
No.
System
drains
per cycle
Flush water used
per day
(flow at
7USGAL/min)
Program 1 Up to 4 <0.5 300Usgal/d
(1135L/d)
2 -- 14USgal/d (53L/d)
Program 2 Up to 4 <0.5Peaks to
1.0NTU, <5%
of time
300Usgal/d
(1135L/d)
3 -- 21USgal/d (80L/d)
Program 3 Up to 6 <0.5 Peaks to
1.0NTU, <5%
of time
400Usgal/d
(1510L/d)
4 -- 28USgal/d
(106L/d)
Table 5-MWF4100AWS and MWF4200AWS Controller Program Selection