Maytag mwf4100aws Water System User Manual


 
MAYTAG Whole Home Water Filtration System Owners Manual MA1-5
November 2003
24
Advanced Controller
Program Recommended
household
occupancy
(persons)
(Raw) Source
water turbidity
(NTU)
Daily household
water consumption
No.
Flushes
per cycle
No.
System
drains
per cycle
Flush water used
per day
(flow at
7USGAL/min)
Program 1 Up to 4 <0.5 300Usgal/d
(1135L/d)
2 -- 14Usgal/d (53L/d)
Program 2 Up to 6 <0.5
Peaks to
1.0NTU, <5%
of time
400Usgal/d
(1510L/d)
4 -- 28Usgal/d
(106L/d)
Program 3 Up to 4 <1.0
Peaks to
5.0NTU, <5%
of time
300Usgal/d
(1135L/d)
2 1 13Usgal/d (49L/d)
Program 4 Up to 6 <5.0
Peaks to
10.0NTU,
<5% of time
400Usgal/d
(1510L/d)
2 2 18Usgal/d (68L/d)
Table 6-MWF4300AWS Controller Program Selection
Winterization Procedure
All service and maintenance is to be performed by a MAYTAG Services Qualified Service
Technician.
Some of the necessary tools required are available for purchase from MAYTAG. If the Stainless
Steel Prefilter requires cleaning, you may want to collect enough water in a suitable container
from a tap for cleaning the Stainless Steel Prefilter prior to beginning this procedure. All water in
the house will be shut off for the duration of this procedure. Be sure to wear clean waterproof
gloves during this procedure and to read through the procedure first before beginning.