Maytag mwf4100aws Water System User Manual


 
MAYTAG Whole Home Water Filtration System Owners Manual MA1-5
November 2003
25
Never ever use any AUTOMOTIVE type antifreezes when winterizing drinking systems. This
may result in serious injury or death.
The use of cheaper ‘non-propylene glycol based’ plumbing or RV antifreezes may damage the
System’s internal components voiding all warranties. Antifreeze used must be plumbing
antifreeze, rated for –50
o
C (-58 F), consisting primarily of propylene glycol and must not contain
any ethanol or alcohols.
Propylene glycol will provide protection of the System against freezing down to –40
o
C (-40 F) as
long as the proportion of preservative to water is correct. The amount and concentration of the
preservative solution has been selected to take into account water that is not easily drained from
the System. This procedure only protects the MAYTAG Whole Home Water Filtration System
from freezing and does not protect the rest of the house.
Do not use hot water during commissioning or maintenance of the System. It is possible that if a
hot water tap is used, high levels of factory preservative, chlorine or MAYTAG MC1 Cleaning
Solution will enter the hot water tank and cause personal injury, illness and/or death. It is
recommended to close the hot water inlet valve during commissioning or maintenance of the
System and to reopen the hot water inlet valve at the end of the procedure.
When filling System, fill slowly and watch for leaks to avoid excessive water dripping onto floor.
During this procedure DO NOT open the Bypass Valves as this will allow potentially
contaminated water into the household distribution system. Contaminated water may lead to
personal injury and/or death.
Chlorine bleach must be less than 3 months old. The active percentage reduces with time.
This procedure does not disinfect all of the household lines. It is strongly recommended that all
of the lines are sanitized as water left in pipes may be microbially unsafe.
When treating surface water sources a maximum prefilter mesh size of 30 micron is required.
Failure to provide this level of prefiltration may lead to System damage. A damaged System will
not perform effectively, endangering the homeowner or occupant through possible serious
personal injury and/or even death.
Do NOT allow the preservative (plumbing antifreeze) to drain onto the ground, into a septic bed,
storm sewer or any body of water. Check the plumbing antifeeze manufacturers directions and
warnings for more information.