XR20 User Menu 17
Using the Zone Monitor Function
1. Access the User Menu.
2. Press the COMMAND key until ZONE MONITOR? displays.
3. Press any one of the Select keys.
The keypad displays PERIM ALL NBR .
4. Select PERIM to place all disarmed perimeter zones into Zone
Monitor. PERIM is displayed only on All/Perimeter and Home/
Away systems.
4a. The keypad displays PERIM? ADD RMV.
4b. Select ADD to add all perimeter zones to Zone Monitor.
4c. Select RMV to remove all perimeter zones.
5. Select ALL to place all disarmed perimeter and interior zones
into Zone Monitor.
5a. The keypad displays ALL? ADD RMV.
5b. Select ADD to add all disarmed zones to Zone Monitor.
5c. Select RMV to remove all disarmed zones.
6. Select NBR to enter a specific zone number for zone monitor.
7. If NBR is selected, the keypad displays ZONE : - ADD RMV.
7a. Enter any zone number and select ADD to add this zone.
7b. Enter any zone number and select RMV to remove the zone.
8. The zone number automatically disappears and a new zone
number can then be entered in step 7a.
System Test
User Code Level: Master or Standard.
Function: System Test is used to test the battery, alarm bell or
siren, and communication to a central station. The System Test
function begins automatically as soon as you select it.
Using the System Test Function
1. Access the User Menu.
2. Press the COMMAND key until SYSTEM TEST? displays.
3. Press any one of the Select keys. The system test begins
automatically and the keypad displays:
1) BELL SOUNDING during a two second bell test, then:
2) BATTERY - OKAY or BATTERY - TRBL to indicate the
condition of the battery, then:
* 3) TRANSMIT TEST and ATTEMPT NO : 1 during the
transmit test, then:
4) TRANSMIT OKAY or TRANSMIT FAILED to show the
results of the transmit test, then:
5) TEST END to indicate the System Test is complete.
6) You can end the transmit test by pressing the Back Arrow
key.
* The transmit test does not operate on local systems.
Testing your system's burglary protection: The System Test
function should be part of your weekly testing and should be
followed by placing the interior and perimeter burglary devices in
Zone Monitor mode. This allows you to open and then close each
protected door and window while listening for the keypad to beep
confirming its operation. See Zone Monitor.