Lenoxx Electronics L30 BF-2 Indoor Fireplace User Manual


 
PLANNING YOUR INSTALLATION
PAGE 6
CLEARANCES TO COMBUSTIBLE MATERIALS
These appliances can be installed in most residential room
configurations, parallel to a rear or adjacent wall, or in an
alcove that allows for the minimum clearances to combus-
tible surfaces. Your local building inspector should review
your plans prior to installation.
When installing this appliance, provide adequate clear-
ances around air openings and adequate clearances for
purposes of servicing and proper operation.
As determined through the safety certification of this unit,
a minimum clearance to combustible materials must be
maintained around specific areas of the gas appliance.
(See Figures 1, 2 and 3)
The clearances listed here are minimum distances and
only apply in the configuration shown. Do not use clear-
ances from one installation configuration with clearances
from another to obtain closer clearances.
Top of appliance (min.) 36” (inches)
This includes any projections such as shelves, window sills,
mantels, etc. above the appliance.
Back Wall 2" (inches)
Side Wall 12" (inches)
Corner (45° angle) 4" (inches)
stove corners to wall
Ceiling Minimum 65" (inches) from floor
Alcove Min. Height 65" (inches) from floor
Alcove Min. Width 54" (inches)
Alcove Max. Depth 24" (inches) from unit face.
The stove can not be placed deeper into an alcove than 24” from
the stove face to alcove opening.
Floor 0 inches
FLOOR PROTECTION
When installed directly on carpeting, tile or other com-
bustible material other than wood flooring, the appliance
shall be installed on a metal or wood panel extending the
full width and depth of the appliance ( see note below).
Notes:
Ceramic tile is non-combustible and does not require
a wood or metal panel under the appliance.
Models with a pedestal base where base dimensions
exceed width and depth of stove body, qualify as the
floor protection
Rear Wall or Alcove
Corner
Rear Wall or Alcove
Fig. 1
Fig. 2
Fig. 3