Lenoxx Electronics L30 BF-2 Indoor Fireplace User Manual


 
CARE AND OPERATION
PAGE 13
“BREAK-IN” PERIOD
The finish on this appliance is a high temperature paint
that requires time and temperature to completely cure.
The curing process will take 2 or 3 burns (heat up and
cool down periods). We recommend that you ventilate
the house during the initial burns. The paint emits non-
toxic odors during this process.
KEEP YOUR HOUSE WELL VENTILATED DURING
THE CURING PROCESS TO PREVENT ACTIVATION
OF YOUR HOME SMOKE DETECTOR.
Do not turn on a blower during the break-in period. Do
not place anything on the stove surface until the paint is
completely cured. Do not attempt to repaint the stove
until the paint is completely cured. If the surface later
becomes stained or marred, it may be lightly sanded
and touched up with spray paint (See Small Area Paint
Touch-Up, page 16). Paint is available at your local
authorized Lennox Hearth Products dealer. Never at-
tempt to paint a hot stove.
CIRCULATION BLOWER OPERATION
The speed of the circulation blower is controlled using
the speed control rheostat (see following illustration) on
the left hand side of the control panel. The blower sys-
tem is designed with a variable speed control allowing
an infinite range of blower settings to meet the cus-
tomer’s needs. With the rotary switch turned fully CCW
3, the blower is off. Turning the switch CW 2 will acti-
vate the blower at its maximum speed. Further rotation
of the switch in the CW direction will reduce the speed
of the blower. At approximately 270° of CW 2 rotation,
the switch provides a minimum setting for blower
speed.
Thermostatic feature: With the control switch in any
“ON” position, the circulation blower is designed to
automatically begin operation approximately 12 minutes
after lighting the main burner. The blower will turn off
approximately 15 minutes after the main burner is shut-
off.