Lennox International Inc. DAVE LENNOX SIGNATURE COLLECTION GAS FURNACE Furnace User Manual


 
Page 36
BLOWER DATA
SL280DF090V60C BLOWER PERFORMANCE (less lter)
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm Second Stage Heating Speed - cfm
+24% 1540 1695
+18% 1465 1615
+12% 1390 1530
+6% 1320 1450
Factory Default 1245 1365
–6% 1170 1285
–12% 1095 1205
–18% 1020 1120
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm Second Stage Cooling Speed - cfm
Low Medium-Low Medium-High
2
High Low Medium-Low Medium-High
2
High
+ 1125 1250 1400 1590 1585 1770 2000 2275
Factory Default 1020 1135 1285 1445 1420 1610 1845 2,050
900 1005 1155 1280 1305 1395 1645 1875
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specic DIP Switch
Settings.
2
Factory default setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28%, 38%, 70% and 100% of the selected second stage cooling speed - minimum 500 cfm.
Lennox Harmony III™ Zone Control Applications - Minimum blower speed is 480 cfm.
SL280DF110V60C BLOWER PERFORMANCE (less lter)
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm Second Stage Heating Speed - cfm
+24% 1645 1810
+18% 1565 1720
+12% 1485 1635
+6% 1405 1545
Factory Default 1325 1460
–6% 1245 1370
–12% 1170 1285
–18% 1090 1195
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm Second Stage Cooling Speed - cfm
Low Medium-Low Medium-High
2
High Low Medium-Low Medium-High
2
High
+ 1075 1225 1370 1530 1500 1755 1915 2120
Factory Default 945 1120 1230 1385 1360 1585 1770 1960
880 985 1135 1235 1225 1405 1595 1760
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specic DIP Switch
Settings.
2
Factory default setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28%, 38%, 70% and 100% of the selected second stage cooling speed - minimum 500 cfm.
Lennox Harmony III™ Zone Control Applications - Minimum blower speed is 485 cfm.