Lennox Hearth LMBV-42RMN Indoor Fireplace User Manual


 
2
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Gas Orifice
Type Size Elevation
0 - 4500'
(0 - 1370 m)
0 - 4500'
(0 - 1370 m)
Natural
Propane
(0.065)
#37
(0.104)
TABLE OF CONTENTS
Introduction..................................... page 2
General Information......................... page 2
Operation/Care of Your Appliance.... page 3
Damper & Outside Air Controls ....... page 4
Manual Limit Switch ........................ page 5
Maintenance .................................... page 6
Millivolt Appliance Checkout............ page 6
Electronic Appliance Checkout......... page 6
Maintenance Schedule..................... page 7
Log and Rockwool Placement ......... page 8
Wiring Diagrams.............................. page 9
Lighting Instructions – Millivolt ....... page 10
Lighting Instructions – Electronic.... page 12
Troubleshooting Guide – Millivolt ..... page 14
Troubleshooting Guide – Electronic .. page 15
Warranty.......................................... page 16
Product Reference Information ....... page 16
Replacement Parts .......................... page 16
Accessory Components ................... page 17
Replacement Parts List..................... page 18
These appliances are designed to operate on
natural or propane gas only. The use of
other fuels or combination of fuels will de-
grade the performance of this system and
may be dangerous.
Input of appliance is 30,000 BTU/HR.
CONGRATULATIONS!
In selecting this LENNOX B-vented gas appliance you have chosen the finest and most
dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a
wood burning fireplace. Welcome to a Family of tens of thousands of satisfied LENNOX
Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please pay
special attention to the safety instructions provided in this manual. The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your LENNOX product.
INTRODUCTION
The millivolt appliances are designed to oper-
ate on either natural or propane gas. A millivolt
gas control valve with piezo ignition system
provides safe, efficient operation.
The electronic appliances are designed to op-
erate on either natural or propane gas. An
electronic intermittent ignition system pro-
vides safe, efficient operation. External electri-
cal power is required to operate these units.
GENERAL INFORMATION
Note: Installation and repair should be per-
formed by a qualified service person. The appli-
ance should be inspected annually by a quali-
fied professional service technician. More fre-
quent inspections and cleanings may be re-
quired due to excessive lint from carpeting,
bedding material, etc. It is imperative that the
control compartment, burners and circulating
air passage ways of the appliance be kept clean.
S'assurer que le brùleur et le compartiment
des commandes sont propres. Voir les in-
structions d'installation et d'utilisation qui
accompagnent l'apareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
Due to high temperatures the appliance should
be located out of traffic and away from furni-
ture and draperies. Locate furniture and win-
dow coverings accordingly.
Nominal operating pressures for the manifold
side of the gas control system are; 3.5 inches
water column (0.87 kPa) for natural gas mod-
els and 10 inches water column (2.49 kPa) for
propane gas models.
These appliances comply with National Safety
Standards and are tested and listed by War-
nock Hersey (Report No. 3106807) to ANSI
Z21.50 - latest edition (in Canada, CSA 2.22 -
latest edition), and CAN/CGA-2.17-M91 in both
USA and Canada, as vented gas fireplaces.
Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas
Code, ANSI Z223.1 (NFPA 54). (In Canada, the
current CAN/CGA B149 installation code.) Elec-
trical wiring must comply with local codes. In
the absence of local codes, installation must
be in accordance with the National Electrical
Code, NFPA 70 - (latest edition). (In Canada,
the current CSA C22.1 Canadian Electric Code.)
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.
WARNING: THESE FIREPLACES ARE
VENTED DECORATIVE GAS APPLI-
ANCES. DO NOT BURN WOOD OR OTHER
MATERIAL IN THESE APPLIANCES.
WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE. REFER TO
THIS MANUAL. FOR ASSISTANCE OR
ADDITIONAL INFORMATION CONSULT
A QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.
WARNING: ELECTRONIC MODELS OF
THESE APPLIANCES ARE EQUIPPED
WITH A THREE-PRONG (GROUNDING)
PLUG UTILIZED IN CONNECTING THE
ELECTRONIC COMPONENTS TO THE
JUNCTION BOX IN THE LOWER COM-
PARTMENT. THIS GROUNDING PLUG
PROVIDES PROTECTION AGAINST
SHOCK HAZARD AND SHOULD BE
PLUGGED DIRECTLY INTO THE PROP-
ERLY GROUNDED THREE-PRONG RE-
CEPTACLE. DO NOT CUT OR REMOVE
THE GROUNDING PRONG FROM THE
PLUG.