Lennox Hearth 32FS Stove User Manual


 
27
Air Wash
A small slot in the door that allows room air to be pulled into the
firebox and pours over the inside surface of the door glass to inhibit
the build up of soot.
Auger
A motor powered screw device that transfers the fuel from the hopper
to the feed chute to deliver pellets to the UltraGrate™.
Auger Motor
Drives the Auger. Motor specifications are: 0.5 Amp, 1.25 RPM
(revolutions per minute).
Blower, Room Air (Convection)
The blower function is to transfer the heat from the appliance to heat
the room air.
Blower, Exhaust (Combustion)
It has a radial impeller to deliver more air to the UltraGrate™. It pulls
air into the UltraGrate by creating a negative pressure. This is done
by extracting the exhaust gases out of the firebox and pushing the
exhaust downstream to the flue exit.
Thermal Switches, High Limit
There are three of these high-limit thermal switches on this model.
If a temperature reaches the high limit temperature, the reset switch
will “trip” and stop the flow of electricity to the auger motor. The
thermal switches will not reset until they have cooled below low reset
temperature).
- Auto Reset Thermal Snap Switch for Room Air Blower (L250-
30F, N/C*) – This switch will trip at 250° F and will automatically
reset when it reaches a temperature of 220° F. This switch is
located on the room air blower jacket and is designed to detect
an overfire condition.
-
Auto Reset Thermal Snap Switch for Combustion Air Inlet
(L250-30F, N/C*)
This switch will trip at 250° F and will auto-
matically reset when it reaches a temperature of 220° F. This
switch is designed to detect reversed flow or excessive heat
in the ashpan area. This switch is located on the firebox base
behind the convection jacket, directly above the ashpan. This
switch is most easily accessed by removing the ashpan
-
Manual Reset Thermal Snap Switch for Feed Chute (L300-145F,
N/C*) This switch will trip at 300° F and will not be resettable
until it reaches a temperature of 155° F. This switch is designed
to detect if heat from the fire is approaching a path toward the
hopper. If this switch trips it must be manually reset. To reset,
open left side access door (facing stove), locate switch on the
side of the auger tube and press the red button in the center until
it clicks into the reset position.
Thermal Switch, Low Limit (Ceramic, F140-20F, N/O*) - This "proof
of fire" switch will close at 140° F and will not open until it reaches
a temperature of 120° F. This switch is located on the combustion
blower (behind the right side panel). It is designed to shut down the
stove (auger motor and both blowers) if it does not detect the heat of
a fire at the end of the initial startup period.
Hopper Lid Switch
It is located on the left hinge area inside the hopper. It detects whether
the hopper lid is open and will turn off the auger motor if the hopper
lid is not properly closed. When opening the hopper when refueling,
do not allow the hopper lid to remain open too long or the fire may
extinguish. NEVER DISCONNECT OR BYPASS THIS SWITCH FOR
ANY REASON.
Hopper
The hopper is where the pellets are stored.
Heat Output Button
It controls power to the feed system - auger motor and combustion
blower. Use the heat output button to adjust to any of the five feed
rate settings (which controls the burn rate).
Pressure Switch
A safety device used to shut off the feed system (auger motor) if there
is too much back pressure in venting system. Some possible causes
are as follows:
The venting system is obstructed.
High altitude or other misc. environmental conditions affecting
exhaust flow.
Improper venting system.
The Pressure Switch is located inside the right access door right next
to the combustion blower.
UltraGrate (Burn Grate)
This is where combustion occurs and may be referred to as the “Burn
Grate”.
* N/C = Normally Closed
N/O = Normally Open
Figure 35 - WIRING DIAGRAM 120 V AC
COMPONENT DEFINITIONS
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
MATERIAL SPECIFICATIONS:
MATERIAL - WHITEPOLYESTER 740 2. MILPRINT TREATED
ADHESIVE - PERMANENT ACRYLIC ADHESIVE
MATERIAL SIZE – 4” X 10”
TEXT – BLACK
DIELINE WILL NOTPRINT
SUPPLIER:
INTERNATIONAL GRAPHICS & NAMEPLATE, INC.
14413 NE 10TH AVE., SU. C
VANCOUVER, WA 98685
800-458-3355
REV DATE
ALTERATIONS
PREPARED BY /
& CHKR
NC 06/04/2008 T-3654 New Release MSJ / JB / JSH / CRZ
TOLERANCE UNLESS OTHERWISE NOTED LINEAL DIM. SQUARENESS, NOTCH u BRAKE RES. +/- 1/32, ANGLES +/- 2°, HOLES
UP TO 1/4” +/- .004, 1/4” +/- .005, 1/4” TO 1” +/- .010, OVER 1” +/- 1/64”
Lennox Hearth Products ENGINEERING DEPT.
Orange, California
DESCRIPTION: WIRE DIAGRAM LABEL - MONTAGE 32FS
FOR FINISH SPECS REFER TO ES-0049
PAINT
NONE
INSIDE
SHEET NO. DWG.
1 OF 1 NO.
537039-01
PAINT
NONE
OUTSIDE
THIS PRINT IS THE PROPERTY OF LENNOX HEARTH PRODUCTS
PAGE 1OF 1
DO NOT SCALE THIS PRINT
2-BLK
5-WHT
HOT
GND
NEUT
GRN
CONV
BLOWER
3-BLK
AUGER
MOTOR
IGNITER FUSE
IGNITER
L
N
1-BLU
4-ORG
2-BLK
J P
J P
COMB
BLOWER
THERMOSTAT
CONNECTOR
YEL
YEL
HI-LIMIT
AUTO-RESET
SWITCH N/C
HI-LIMIT
AUTO-RESET
SWITCH N/C
PRESSURE
SWITCH
N/C
HOPPER
LID SWITCH
N/C
HI-LIMITMANUAL
RESETTABLE
SWITCH N/C
LO-LIMIT AUTO-RESETSWITCH N/O
ONCOMBUSTIONBLOWERHOUSING
NOTE:SWITCHCONDITIONS
GIVENAT ROOM TEMPERATURE,
STOVEOFF
N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN
= FEMALE DISCONNECT
= MALE DISCONNECT
= STUD CONNECTION
POWER DISCONNECT
1-BLU
3-RED
1-BLU
P/N 537039-01 Rev. NC
Montage
TM
32FS
Wire Diagram
2
4
6
1
3
5
J = JACK
P = PLUG
ONAUGER
TUBE
LEFT HOPPER
LID HINGE
AREA
INSIDE RIGHT
ACCESS DOOR
1
3
2
4
6-BRN
ABOVEROOM
AIR BLOWER
DIRECTLY
ABOVE
ASHPAN
2-BLK
IGN 08-2302