Lennox Hearth 32FS Stove User Manual


 
15
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Notes:
It is not recommended to terminate
exhaust vent on the prevailing wind
side of the house.
Wall
3” (75 mm) Minimum clearance
between wall and pipe. If you vent to
the furthest wall, the vent pipe must
maintain a 3” clearance parallel to
the other wall.
Top View Illustration
Wall
1" Min.
1" Min.
6” (152 mm)
Minimum
Hearth Pad / Floor Protection
12”(305 mm) From
Ground or Other Surface
45 Degree
Elbow
2” (51 mm)
Minimum
12” (305 mm)
Minimum From
Outer Wall
Figure 17 - Montage 32FS, Parallel Through the Wall
Wall
Outdoors
Standard Horizontal Installation Configurations
Montage™ 32FS
Note:
Horizontal run of pipe requires
1/4” (7 mm) rise per foot.
Figure 16 - Montage 32FS, Corner Through the Wall