Juniper Networks IDP250 Home Security System User Manual


 
Traffic Interface Ports on page 7
IDP250 Technical Specifications on page 59
Power Supply
The appliance has one power supply. It is a field replaceable unit (FRU).
Related Topics Replacing a Power Supply on page 53
Hard Drive
The appliance has one 80 GB hard drive. It is not a field replaceable unit (FRU).
Fans
When the system is cool, appliance fans spin at a slower speed to reduce noise and
save energy. As the system heats up, the fans run at a faster speed. In the event of
fan failure, the appliance fault LED blinks and the remaining fan or fans run at full
speed until the failed fan is replaced.
The fans for this model are not field replaceable units (FRUs).
System Status LEDs
Table 6 on page 4 describes system status LED states.
Table 6: System Status LED States
DescriptionStatusLED
System is powered on.Solid greenPower
System is powered off.Off
Hard disk is active.Flashing amberHard Drives
Hard drive has no activity.Off
Power failure.Slowly blinking redFault
Fan failure.Quickly blinking red
Overheating.Solid red
Heat and power are normal.Off
4 Power Supply