When decorative 6 pipe is installed to cover
the venting any Listed Flexible Gas liner must
be connected directly to the stoves draft hood.
Use of single wall connector pipe as a vent is
prohibited for use with the Allagash B-Vent stove.
A firestop is required at every floor.
Any venting that is exposed above the first
floor, regardless of attic space or living space,
must be enclosed. Always maintain the
required clearance from all sides of the vertical
vent system according to manufacture.
Installation of any components not
manufactured or approved by Jøtul or failure
to meet all clearance requirements will void
all warranties and could result in property
damage, bodily injury, or serious fire.
Never modify any venting component, or use
any damaged venting product.
THE GAS APPLIANCE AND VENT
SYSTEM MUST BE VENTED DIRECTLY
TO THE OUTSIDE OF THE BUILDING,
AND NEVER ATTACHED TO A
CHIMNEY SERVING A SOLID FUEL OR
GAS BURNING APPLIANCES.
BE SURE TO MAINTAIN THE PROPER
CLEARANCES TO COMBUSTIBLES AS
DEFINED IN THIS MANUAL AND IN
THE INSTRUCTIONS PROVIDED WITH
EACH VENTING COMPONENT.
When installing at an altitude above 2000 the
minimum vertical rise
becomes 12 from the
draft hood.
If more than two feet of venting is exposed to
the outside, the entire exterior vent system
must be enclosed in an insulated chase system.
8
Listed termination
cap required
Storm collar
required
Recommended
damper sealing plate
to seal flue chamber
to prevent heat loss
Allagash B-Vent gas
stove
Always maintain
the proper
clearance to mantel
and trim
Allagash B-Vent gas stove vented into a
masonry or prefabricated fireplace.
Maximum
offset is 4
Type B vent or
Listed Flexible
Gas Liner. On
outside chimneys
Jøtul recommends
the use of Type B
vent to help keep
the gases warm and
rising.
max. height 35
min. height 7
Top sealing
achor plate
WARNING: FAILURE TO POSITION THE PARTS IN
ACCORDANCE
WITH THIS DIAGRAM OR FAILURE TO USE
ONLY
PARTS SPECIFICALLY APPROVED WITH THIS
APPLIANCE
MAY RESULT IN P ROPERTY DAMAGE OR
PERSONAL
INJURY.