8. Push in control knob all the way and hold in.
Immediately light the pilot by triggering the spark
ignitor (push the red button repeatedly) until pilot
lights. Continue to hold the control knob in for
about one minute after the pilot lights. Release
knob and it should spring back. The pilot should
remain lit. If it goes out, repeat Steps 5 through 8.
If knob does not
return when released,
stop and immediately
call your service
technician or gas
supplier.
If pilot will not stay
lit after several tries,
turn the control knob
to OFF and call your service technician or gas
supplier.
9. Turn gas control knob counterclockwise
to ON.
10.Turn the stove ON/OFF switch to ON, or set
thermostat (if used) to desired temperature.
FOR YOUR SAFETY, READ BEFORE LIGHTING.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO THE APPLIANCE:
LIGHTING INSTRUCTIONS
WARNING:
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
A. This appliance has a pilot which must be lit
by hand. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING, smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle to the floor.
WHAT TO DO IF YOU SMELL GAS:
Extinguish any open flame.
Open windows.
Do not light any appliance.
Do not touch any electrical switches.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbors phone.
If your gas supplier cannot be reached, call the
fire department.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it.
Call a qualified technician. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.
1. STOP! Read the safety information above.
2. Access the lower controls.
3. Turn the stove ON/OFF switch to OFF, or set the
thermostat to lowest setting (if used).
4. Confirm that the gas supply line shut-off valve is open.
5. Push in gas control knob slightly and turn clockwise
to OFF.
NOTE: Knob cannot be turned from PILOT to OFF
unless the knob is pushed in slightly. Do not force.
6. Wait five (5) minutes to clear out any gas. If you then
smell gas, STOP! Follow B in the safety information
above on this page. If you do not smell gas, go to the
next step.
7. Push in gas control knob slightly and turn counter-
clockwise to PILOT.
PILOT ASSEMBLY
OFF
PILOT
ON
CONTROL VALVE
Control
Knob
1. Turn ON/OFF switch to OFF. The pilot will remain lit for
normal service.
2. For complete shutdown, turn ON/OFF switch to OFF.
3. Access the lower controls.
4. Depress gas control knob slightly and turn clock-
wise to OFF. Do not force.