Jenn-Air W10323791 Gas Heater User Manual


 
3
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Parts supplied
Check that all parts are included.
Anti-tip bracket kit
NOTE: Anti-tip bracket must be securely mounted to subfloor.
Thickness of flooring may require longer screws to anchor
bracket to subfloor. Longer screws are available from your local
hardware store. See “Install Anti-Tip Bracket” section.
Gas pressure regulator
Burner grates
Burner heads and caps
Griddle drip tray (on griddle models)
LP orifice package (W10323791)
Conversion label (8114P522-60)
NOTE: The cooktop is manufactured for use with Natural gas. To
convert to LP gas, see the “Gas Conversions” section.
Parts needed
All models must be installed with a backguard if installing at zero
clearance to a combustible backwall. See “Cabinet Dimensions”
in the “Location Requirements” section for installation
requirements.
30" (76.2 cm) Adjustable Backguard
Order Part Number 8285148
36" (91.4 cm) Adjustable Backguard
Order Part Number 8284756
48" (121.9 cm) Adjustable Backguard
Order Part Number 8284755
22" (55.9 cm) Backsplash with Dual-Position Shelf for
30"(76.2 cm) Ranges
Order Part Number W10285447
22" (55.9 cm) Backsplash with Dual-Position Shelf for
36" (91.4 cm) Ranges
Order Part Number W10285448
22" (55.9 cm) Backsplash with Dual-Position Shelf for
48" (121.9 cm) Ranges
Order Part Number W10285449
To order, see the “Assistance or Service” section of the Use
and Care Guide.
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See “Electrical Requirements” and
“Gas Supply Requirements” sections.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
High Altitude Conversion
To convert the range for elevations above 6,560 ft (1999.5 m),
order a High Altitude Conversion Kit.
Part Number W10324363 - LP high altitude
Part Number W10324365 - Natural gas high altitude
To order, see the “Assistance or Service” section of the Use and
Care Guide.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to wall behind range.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death or serious burns to children and adults.
Tape measure
#2 Phillips screwdriver
¹⁄₈" x 4¼" flat-blade
screwdriver
Level
Drill
Wrench or pliers
Pipe wrench
Adjustable wrench or
⁵⁄₈" wrench
³⁄₈" drive ratchet
¹⁄₈" drill bit
¹⁵⁄₁₆" combination wrench
¹⁄₄", ³⁄₈", ⁵⁄₁₆" nut drivers
³⁄₁₆" carbide tip masonry bit
Marker or pencil
Pipe-joint compound
resistant to LP gas
Noncorrosive leak-detection
solution
Tubing cutter
For LP/Natural Gas
Conversions
T15 Torx
®†
screwdriver
⁷⁄₈" socket
Adjustable wrench
½" deep-well socket
7 mm nut driver
Masking tape
A. Anti-tip bracket
B.#8-18 x 1" Phillips head screws (4)
†®TORX is a registered trademark of Saturn Fasteners, Inc.
A
B