Jenn-Air W10323791 Gas Heater User Manual


 
13
GAS CONVERSIONS
IMPORTANT: Gas conversions from Natural gas to LP gas must
be done by a qualified installer.
LP Gas Conversion
1. Turn the manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1. Remove screws from kick plate.
2. Push up on kick plate to release plate from shoulder screws.
3. Gently lay kick plate aside to avoid scratching the stainless
steel.
4. Locate the gas pressure regulator at the left rear of the range.
5. Remove the gas pressure regulator cap by using a large flat-
blade screwdriver, turning the regulator cap
counterclockwise.
NOTE: Do not remove the spring beneath the cap.
A.To range
B. Shutoff valve (closed position)
C.Gas supply line
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
B
C
A.Kick plate
B.Remove these screws.
A. Gas pressure regulator
A
B
A