6. Place the canopy trim ring then the canopy over the adapter
as shown in Figure 15.
7. Place the low profile washer (lip up) into the canopy as shown
in Figure 15 fitting the notch in the low profile washer over the
adapter set screw and hook.
Figure 15 - Assembling canopy for low profile mounting
8. Rotate the canopy until the arrow on the low profile washer
aligns with the tab hole on the canopy as shown in Figure 15.
9. Align the holes in the low profile washer with the holes in the
adapter and assemble securely with the three #8-32 x 1” screws.
hanging the fan
1. Raise the fan and place the hook through the loop on the ceil-
ing plate as shown in Figure 16. Use the note and arrow en-
graved in the ceiling plate to assist in determining the direc-
tion to assemble.
WARNING: Fan may fall if not assembled as directed in
these installation instructions.
Figure 16 - Hanging the fan
wiring the fan
1. Disconnect the power by turning off the circuit breakers to
the outlet box and associated wall switch location.
2. Connect the wires as shown in Figure 17. To connect the wires,
twist the bare metal leads together. Place a wire nut over the
intertwined length of wire and twist clockwise until tight as.
CAUTION: Be sure no bare wire or wire strands are vis-
ible after making connections.
All wiring must be in accordance with national and local
electrical codes and ANSI/NFPA 70. If you are unfamiliar
with wiring, you should use a qualified electrician.
Figure 17 - Wiring the fan
installing the canopy
1. Rotate the fan 180º clockwise from the initial position when
hanging the fan. The arrows on the hanger ball and on the
ceiling plate should be pointing in the same direction and
should be pointing towards the tab hole on the canopy. Refer
to Figure 18.
Figure 18 - Rotating the fan
For Flush Mounting: The arrows on the low profile washer
and on the ceiling plate should be pointing in the same direc-
tion and should be pointing towards the tab hole on the
canopy.
2. Hook the tab hole over the tab on the ceiling plate as shown in
Figure 19.
Hook
Loop
Canopy Trim Ring
Arrow on the
Low Profile
Washer
Low Profile Washer
Canopy
Tab Hole
Power
Wires
in
Ceiling
Black
White
Bare or Green
2 x 4 Brace
Outlet Box
Ceiling Plate
Approved
Connectors
Green Ground Wire from
Hanger Pipe (not present
with flush mounting
option)
White
Black
41810-01_rev 8-20-04 v 3.pmd 8/21/04, 4:36 PM6