Table 5.3.11-3: Heading Input Select Type 3
CHANNEL
429RX_7
CONNECT TO: AHRS
Format: ARINC 429 (High Speed)
Fault Designation: AHRS BUS
Bus Type: Basic
A = J2-23
B = J2-6
Data
Magnetic Heading
True Heading
Reference
6.2.32
6.2.37
Label
320
314
Sig. Bits
15
15
Range
±180 degrees
±180 degrees
Signal Type
Basic
Basic
Resolution
0.0054931640625
0.0054931640625
Rate (ms)
10-20
25-50
Table 5.3.11-254: Heading Input Select 254
CHANNEL
429/422RX_1
CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
True Heading
Reference
6.2.32
Label
314
Sig. Bits
15
Range
±180 degrees
Signal Type
Basic
Resolution
0.0054931640625
Rate (ms)
25-50
CHANNEL
429RX_3
CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 2
Bus Type: Basic
A = J2-41
B = J2-40
Data
True Heading
Reference
6.2.32
Label
314
Sig. Bits
15
Range
±180 degrees
Signal Type
Basic
Resolution
0.0054931640625
Rate (ms)
25-50
Table 5.3.11-255: Heading Input Select 255
CHANNEL
429/422RX_1
CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Magnetic Heading
Reference
6.2.32
Label
320
Sig. Bits
15
Range
±180 degrees
Signal Type
Basic
Resolution
0.0054931640625
Rate (ms)
25-50
CHANNEL
429RX_3
CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 2
Bus Type: Basic
A = J2-41
B = J2-40
Data
Magnetic Heading
Reference
6.2.32
Label
320
Sig. Bits
15
Range
±180 degrees
Signal Type
Basic
Resolution
0.0054931640625
Rate (ms)
25-50