Honeywell MK VIII Home Security System User Manual


 
Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-150 REV:
SHEET 254
Table 5.3.10-253: Attitude Input Select Type 253
CHANNEL
429RX_7
CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Roll Angle
Pitch Angle
Body Roll Rate
Body Pitch Rate
Inertial Vertical Speed
Inertial Altitude
Reference
6.2.31
6.2.34
6.2.50
6.2.49
6.2.56
6.2.57
Label
325
324
327
326
365
361
Sig. Bits
14
14
13
13
15
20
Range
±180 degrees
±180 degrees
±128 deg/sec
±128 deg/sec
±32,768 fpm
±131,072 ft
Signal Type
Basic
Basic
Basic
Basic
Basic
Basic
Resolution
0.010986328125
0.010986328125
0.01562500
0.01562500
1.0
0.125
Rate (ms)
10-20
10-20
10-20
10-20
20-40
20-40
CHANNEL
429RX_7
CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 2
Bus Type: Basic
A = J2-41
B = J2-40
Data
Roll Angle
Pitch Angle
Body Roll Rate
Body Pitch Rate
Inertial Vertical Speed
Inertial Altitude
Reference
6.2.31
6.2.34
6.2.50
6.2.49
6.2.56
6.2.57
Label
325
324
327
326
365
361
Sig. Bits
14
14
13
13
15
20
Range
±180 degrees
±180 degrees
±128 deg/sec
±128 deg/sec
±32,768 fpm
±131,072 ft
Signal Type
Basic
Basic
Basic
Basic
Basic
Basic
Resolution
0.010986328125
0.010986328125
0.01562500
0.01562500
1.0
0.125
Rate (ms)
10-20
10-20
10-20
10-20
20-40
20-40
Note: ID 253 may only be used with Category 2 ‘digital’ Barometric Altitude Rate sources, analog sources are not
compatible with Inertial Vertical Speed.
Table 5.3.10-255: Attitude Input Select Type 255
CHANNEL
429/422RX_1
CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Roll Angle
Pitch Angle
Normal Acceleration
Longitudinal Acceleration
Reference
6.2.31
6.2.34
6.2.42
6.2.43
Label
325
324
333
331
Sig. Bits
14
14
12
12
Range
±180 degrees
±180 degrees
±4 g’s
±4 g’s
Signal Type
Basic
Basic
Basic
Basic
Resolution
0.010986328125
0.010986328125
0.000977 g’s
0.000977 g’s
Rate (ms)
10-20
10-20
10-20
10-20
CHANNEL
429RX_3
CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 2
Bus Type: Basic
A = J2-41
B = J2-40
Data
Roll Angle
Pitch Angle
Normal Acceleration
Longitudinal Acceleration
Reference
6.2.31
6.2.34
6.2.42
6.2.43
Label
325
324
333
331
Sig. Bits
14
14
12
12
Range
±180 degrees
±180 degrees
±4 g’s
±4 g’s
Signal Type
Basic
Basic
Basic
Basic
Resolution
0.010986328125
0.010986328125
0.000977 g’s
0.000977 g’s
Rate (ms)
10-20
10-20
10-20
10-20
Note: The output for Normal Acceleration reads 0 g’s nominal when aircraft is on the ground, or during unaccelerated
level flight.