The display will be blanked when the amber “TERR” is present.
The display will Pop Up to Terrain mode as follows:
If all the conditions indicated for the amber “TERR” above are FALSE.
If the display is in normal MFD mode (not HSI backup, or SG backup) AND if label 051 bit 11 transitions from
0 to 1 (rising edge), AND Checklist is not selected on the MFD, AND TCAS Auto Pop Up is not occurring.
The display will change to Map mode.
The display will energize the Terrain selection relays.
The display will annunciate “TERR”.
The display will change to the range indicated by the EGPWS ARINC 429 label 050.