Honeywell MK VIII Home Security System User Manual


 
Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-150 REV:
SHEET 251
Table 5.3.9-252: Navigation Inputs Select 252
CHANNEL
429/422RX_1
CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 1
Bus Type: Basic
A = J2-39
B = J2-38
Data
Glideslope
Localizer
Reference
6.2.30
6.2.33
Label
174
173
Sig. Bits
12
12
Range
±0.8 DDM
±0.4 DDM
Signal Type
Basic
Basic
Resolution
0.0001953125
0.00009765625
Rate (ms)
33.3-66.6
33.3-66.6
CHANNEL
429RX_3
CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 2
Bus Type: Basic
A = J2-21
B = J2-04
Data
Glideslope
Localizer
Reference
6.2.30
6.2.33
Label
174
173
Sig. Bits
12
12
Range
±0.8 DDM
±0.4 DDM
Signal Type
Basic
Basic
Resolution
0.0001953125
0.00009765625
Rate (ms)
33.3-66.6
33.3-66.6
Table 5.3.9-253: Navigation Inputs Select 253
CHANNEL
429/422RX_1
CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Glideslope
Localizer
Reference
6.2.30
6.2.33
Label
174
173
Sig. Bits
12
12
Range
±0.8 DDM
±0.4 DDM
Signal Type
Basic
Basic
Resolution
0.0001953125
0.00009765625
Rate (ms)
33.3-66.6
33.3-66.6
CHANNEL
429RX_3
CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 2
Bus Type: Basic
A = J2-41
B = J2-40
Data
Glideslope
Localizer
Reference
6.2.30
6.2.33
Label
174
173
Sig. Bits
12
12
Range
±0.8 DDM
±0.4 DDM
Signal Type
Basic
Basic
Resolution
0.0001953125
0.00009765625
Rate (ms)
33.3-66.6
33.3-66.6
Table 5.3.9-254: Navigation Inputs Select 254
CHANNEL
429/422RX_1
CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Glideslope
Localizer
PFD Mode Select Word
Reference
6.2.30
6.2.33
6.2.44
Label
174
173
163
Sig. Bits
12
12
Discrete
Range
±0.8 DDM
±0.4 DDM
Type 4
Signal Type
Basic
Basic
Basic
Resolution
0.0001953125
0.00009765625
n/a
Rate (ms)
33.3-66.6
33.3-66.6
250
CHANNEL
429RX_3
CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 2
Bus Type: Basic
A = J2-41
B = J2-40
Data
Glideslope
Localizer
PFD Mode Select Word
Reference
6.2.30
6.2.33
6.2.44
Label
174
173
163
Sig. Bits
12
12
Discrete
Range
±0.8 DDM
±0.4 DDM
Type 4
Signal Type
Basic
Basic
Basic
Resolution
0.0001953125
0.00009765625
n/a
Rate (ms)
33.3-66.6
33.3-66.6
250
Table 5.3.9-255: Navigation Inputs Select 255
CHANNEL
429/422RX_1
CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Glideslope
Localizer
Reference
6.2.30
6.2.33
Label
117
116
Sig. Bits
12
12
Range
±0.8 DDM
±0.4 DDM
Signal Type
Basic
Basic
Resolution
0.0001953125
0.00009765625
Rate (ms)
33.3-66.6
33.3-66.6
CHANNEL
429RX_3
CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 2
Bus Type: Basic
A = J2-41
B = J2-40
Data
Glideslope
Localizer
Reference
6.2.30
6.2.33
Label
117
116
Sig. Bits
12
12
Range
±0.8 DDM
±0.4 DDM
Signal Type
Basic
Basic
Resolution
0.0001953125
0.00009765625
Rate (ms)
33.3-66.6
33.3-66.6