Honeywell LYNXR Series Home Security System User Manual


 
–25–
55 Enabling the 5842 Wireless Dialer
This is an interactive menu mode that is used to enable and program the 5842 Wireless Dialer. When
enabled, the 5842 will interface with the Lynx Control and serve as the system’s primary dialer. The 5842
receives and acknowledges RF messages from the control’s transceiver and, in response, sends reports to the
central station via the dialer. It also sends acknowledgements, supervisory and tamper RF transmissions to
the control. If the wireless dialer has tried unsuccessfully to send a report, the Lynx will attempt to report to
the Central Station via the on-board dialer (if it has been programmed for back-up reporting). The Back-up
reporting option must be selected for Follow-me, Pager and AAV operation (refer to field *49).
LYNX must be connected to the telephone line, if using the Back-up reporting option.
Wireless Dialer Setup
If the wireless dialer is enabled in Field
55, Lynx automatically sends the setup information to the wireless
dialer immediately after exiting the programming mode. Lynx will confirm that the 5842 wireless dialer has
successfully received the setup information by generating three beeps. If the setup information has not been
successfully received by the wireless dialer the Lynx will generate a single beep once per minute and “Fault
Zone 93” will be displayed. To prepare the dialer for setup refer to the Installation Instructions provided
with the 5842 Wireless Dialer.
Note: 1. It takes about 95 seconds for Lynx to transmit the setup information after power has been applied to the
control.
2. Entering Programming mode may take up to 18 seconds if the 5842 Wireless Dialer has been enabled. The
system will display “ - - “ until the Lynx enters Programming mode.
You must refer to these instructions or to the Programming Guide while programming the system because the keypad display
does not show prompt titles. Instead, prompts are indicated by a number/letter combination.
The prompts for
55 are as follows:
Ed Enable Dialer....................................... for enabling the 5842 wireless dialer.
Er Enable Trouble/Supervisory Reports . for defining wireless dialer response to events.*
Ln Response to Phone Line Failure......... for defining console sounder response (trouble/alarm) to a
phone line cut.
Eb Enable Back-up Reporting.................. for enabling the Lynx as a backup dialer.
*The Contact ID® Event Codes for the reports associated with the 5842 wireless dialer include the following:
145 Wireless Dialer Tamper (Alarm)
338 Wireless Dialer Low Battery
341 Wireless Dialer Tamper (Trouble)
342 Wireless Dialer AC Loss (if supported by the 5842 Wireless Dialer being installed)
351 Wireless Dialer Phone Line Cut (if supported by the 5842 Wireless Dialer being installed)
355 (Zone 93) Wireless Dialer Loss of RF Supervision
355 (Zone 000) Interruption of RF Link reported by the 5842 Wireless Dialer
For additional information refer to the Contact ID® Event Codes table.