–21–
Data Field Descriptions
SYSTEM STATUS REPORT CODES (
✻
59–
✻
68)
✻59
Exit Error Report Code
(See notes above)
If the system is armed and an entry/exit or interior zone is still open
after the exit delay time has expired, an alarm will sound at the
keypad and external sounder. If the system is disarmed before the
end of the entry delay that immediately follows, the alarm sounding
will stop and no message will be sent to the central station. The
keypad will display “CA (CANCELED ALARM).”
If the system is not disarmed before the end of the entry delay
mentioned above, and an entry/exit or interior zone is still open, an
“exit alarm” message will be sent to the central station if an Exit
Error report code is selected in this field. The keypad will display
“EA (EXIT ALARM),” and the alarm sounding will continue until
the system is disarmed (or timeout occurs).
An Exit Alarm condition will also result if a fault occurs in an exit or
interior zone within 2 minutes following the end of the exit delay,
and an “Exit Alarm” message will be sent to the central station.
If Contact ID® format has been programmed, the message will
contain the zone number and error code 374 (Trouble–Exit Error). If
4+2 format is used, the digit entered in this field will be sent
followed by the second digit of the programmed alarm code for that
zone. If 3+1 or 4+1 format is used, only the digit entered in this field
will be sent. This message will go to the primary phone no. Under
any of these conditions, no restore message will be sent.
If “0” is entered in this field, no special message will be sent, only
the regular alarm and alarm restore code for the zone.
✻60
Trouble Report Code
(See notes above)
This will be sent if a zone goes into trouble.
✻61
Bypass Report Code
(See notes above)
This will be sent when a zone is manually bypassed.
✻62
AC Loss Report Code
(See notes above)
Timing of this report is random with up to a 4-hour delay. If AC
restores before the report goes out, there is no AC restore report.
✻63
Low Battery Report Code
(See notes above)
This will be sent when a low battery condition exists in the system’s
standby battery.
✻64
Test Report Code
(See notes above)
This is sent periodically to test that the communicator and phone
lines are operational (frequency of report is selected in field
✻
51).
✻65
Open Report Code
(See notes above)
This is sent upon disarming of the system. 2nd digit = user number,
if expanded or 4+2 reporting is selected.
✻66
Arm AWAY/STAY Report Code
(See notes above)
This option allows for independent programming of AWAY and
STAY reports. 2nd digit of report is user number if expanded or 4+2
reporting is selected.
NOTE: OPEN reports are not sent if the associated closing report is
not enabled.
✻67
RF transmitter Low Batt. Report Code
(See notes above)
This is sent in the event that a wireless transmitter low battery
condition exists.
✻68
Cancel Report Code
(See notes above)
This is sent upon disarming of the system after an alarm condition
was reported.
RESTORE REPORT CODES (
✻
70–
✻
76)
✻70
Alarm Restore Report Code, 1st Digit
(See notes above)
Sent when the zone that caused an alarm is restored to its non-
faulted condition. 2nd digit is automatically sent as the 2nd digit of
the zone alarm report code programmed in field
✻
56, if expanded or
4+2 reporting is selected.
✻71
Trouble Restore Report Code
(See notes above)
Sent when a trouble in a zone is restored.
✻72
Bypass Restore Report Code
(See notes above)
Sent when a zone that has been bypassed is unbypassed.
✻73
AC Restore Report Code
(See notes above)
Sent when AC power has been restored after an AC power outage.
✻74
Low Battery Restore Report Code
(See notes above)
Sent when a system low battery condition is restored to normal.