STEP 5 – Program the Communications Module
You must use the 7720P Programming tool to program the IPGSM-DP.
When using the 7720P Programming tool, the values given below are for most installations. Press the [#]
key to accept the displayed default value (xxx) or enter the new value and press the [#] key for the next
prompt. Use the [
Space] key to scroll through a list of options.
1.
(no display)
Connect the 7720P.
2.
7720P PROGRAMMER
Press [#].
3.
Strt Prog Mode? Y/N
Press [Shift] then [Y], then [#].
4.
Program Device? Y/N
Press [Shift] then [Y], then [#].
5.
Com Path Choice (IP&GSM)
Press [Space] to scroll choices; IP&GSM, IP, or GSM. At choice, press [#].
6.
Primary City ID (??)
Enter number 01-99, then press [#].
7.
Primary CS ID (??)
Enter number 01-FE, then press [#].
8.
Primary Sub ID (????)
Enter number 0001-9999, then press [#].
Note: If a Com Path Choice of IP&GSM or IP was selected, prompt 9 will
appear.
9.
Use DHCP? Y/N (Y)
If your router is configured for DHCP, press [Shift] then [Y], then press [#].
Note: If DHCP is not selected (your router is set for a static IP), prompts 10
through 13 will appear.
10.
NIC IP Address:
255.255.255.255
Enter choice, then press [#]. Follow the prompts.
11.
Subnet Mask:
255.255.255.255
Enter choice, then press [#]. Follow the prompts.
12.
Gateway IP Address:
255.255.255.255
Enter choice, then press [#]. Follow the prompts.
13.
DNS Serv IP Addr:
255.255.255.255
Enter choice, then press [#]. Follow the prompts.
14.
Review? Y/N
Enter choice, then press [#]. Follow the prompts.
15.
Create Password? Y/N
Enter choice, then press [#]. Follow the prompts.
16.
Exit Prog Mode? Y/N
Press [Shift] then [Y], then press [#].
17.
DONE
Note: If an error in programming occurs, set the factory defaults (see next topic) and
reprogram the IPGSM-DP.