3. Install the two plastic mounting rails for the LED Display board. They simply snap into the back
plate holes.
4. Connect the LED Display board to its connector, then slide the board into the mounting rails.
(Yellow LED and Buzzer are on top.)
5. Carefully remove the packaging material that surrounds the PowerBoost1.
6. Mount the PowerBoost1 on the three unused standoffs. Use the plastic screw
(prevents shorting)
to secure the upper right corner of the PowerBoost1 and the two metal screws and lock washers to
fasten the left side of the circuit board. Ensure the lock washers are located between the circuit
board and the head of the two metal screws.
7. Mount the Wall Outlet Box to an un-switched facility power outlet and run a conduit to the cabinet.
8. In this step DO NOT plug the transformer in. Route 16AWG wire from the transformer,
through the conduit. Pass the wires through the Ferrite Filter, then loop the wires back through
again making a loop. Connect the wires to the PowerBoost1 AC terminals.
9. Connect and route 16AWG insulated wire from facility power ground (typically a cold water pipe) to
the cabinet's ground post. Ensure all ground connections are tight.
10. Connect the Ethernet cable and the Telco 1 and Telco 2 lines. If you choose to use an optional
Cabinet Tamper Switch (if the control panel supports it) mount and wire it.
Note: The Ethernet cable, Telco 1, Telco 2 lines, and the optional cabinet Tamper Switch (if used)
must be run through conduit.
11. Verify the PowerBoost1 module DIP switches are configured as shown below.
iPGSM-COM-008-V0
PowerBoost1
15
ON
2
3
4
15
ON
2
3
4
(Switch handle = white)
12. Ensure the following:
LED Display board is fully seated.
All wiring terminals and connectors are tight.
All wiring has been completed and secured with cable ties.
13. Install the battery (not supplied). Plug the power transformer in, and attach the battery cable.