10
Atm 1/2/3/4 Zones (512 Only)
ATM zones are omitted by entering one of the ten ATM codes (user
188 to user 197). To select this option enter an ATM code followed by
the ent key. Use the A> key to scroll through the four ATM zone
options (ATM1 to ATM4) and select by pressing the ent key. A
preprogrammed ATM delay time will expire before omitting all ATM
zones with the selected ATM zone type. The zones will be omitted for
the duration of the ATM time-out period and the remaining time in
minutes will be displayed on the initiating keypad. A warning is given
ten and five minutes before the zones are reinstated. The ATM Time-
out period can be extended by entering an ATM code and selecting
1=Reset Access. To manually reinstate ATM zones, enter an ATM
code and select 2=Abort Access.
Forced Set (User Level 3 and Above)
Purpose
When enabled, the Forced Set option allows the user to automatically
omit zones, eligible for omission, which are open when the system setting
routine is started. Zones omitted in this way remain omitted for one set
period only. This option is not available on the Galaxy 512.
Selecting Forced Set
Access the QUICK MENU. Press key 1 followed by the ent key. The
display indicates how many zones have been omitted and the number
of seconds left before setting.
Non-omittable Zones
Some open zones may not be eligible for omission from the system. In
this case the display indicates which zones are open and the exit time is
reset. These zones must be closed before setting can continue.