Grounding
To reduce the risk of static sparking, ground pump.
Check your local electrical code for detailed grounding
instructions for your area and type of equipment.
Pump: Use ground wire and clamp as shown in
F
IG. 3. Order Grounding Wire and Clamp Kit,
Part No. 222011.
Hydraulic Hoses and Fluid Outlet Hoses:
Use electrically conductive hoses only.
Hydraulic Power Supply: Follow manufac-
turer’s recommendations.
Flushing Pails: When flushing, only use metal,
grounded pails. Make firm, metal-to-metal con-
tact between the metal part of the dispense
valve and the pail. Use lowest possible pres-
sure.
Grounding the Pump
To ground pump (See FIG. 3):
1. Remove ground screw (Z) and insert through eye of
ring terminal at end of ground wire.
2. Fasten ground screw back onto pump and tighten
securely.
3. Connect other end of wire to a true earth ground.
F
IG. 3
Z