HP (Hewlett-Packard) 2180206H Plumbing Product User Manual


 
26
Combi HP thermostatic mixer shower
T00297
0D[LPXPWHPSHUDWXUHVWRSPHFKDQLVP
'HFUHDVHVWRSSRVLWLRQ,QFUHDVHVWRSSRVLWLRQ
7
5
,
7
2
1
7
5
,
7
2
1
*URRYHV
7HPSHUDWXUHFRQWUROGLVF
T00296
Fixing screw
Temperature
control knob
Temperature
control disc
Fig.80
As a safety measure the shower has a built-in
maximum temperature stop to prevent you
accidentally exceeding your highest desired
temperature. This is set in the factory to provide
a maximum temperature of 42°C based on the
hot and cold water supplies being 65°C and
15°C respectively at nominally equal pressures.
Procedure
To adjust the maximum temperature stop, first
rotate the temperature knob to the 12 o’clock
position.
Remove the temperature knob trim using a thin
bladed screwdriver (fig.78).
Unscrew the central fixing screw and remove
the temperature control knob (fig.79). Now
remove the temperature control disc, together
with the wavy washer. The control disc houses
the maximum temperature stop mechanism
(fig.80).
To increase the temperature stop setting,
reposition the temperature stop mechanism
clockwise within the arc of the grooves (fig.80).
To decrease the temperature stop setting,
reposition the stop mechanism anti-clockwise
within the arc of the grooves.
When the stop mechanism is set at the preferred
position, refit the temperature control disc
making sure the name ‘TRITON’ is at the bottom.
Replace the wavy washer, then refit the
temperature control knob, making sure it is
replaced in the same attitude as when removed
(i.e. 12 o’clock position).
Refit the central screw and replace the knob
trim.
IMPORTANT:
Only adjust the maximum
temperature stop when the hot water is at its
usual supply temperature.
ADJUSTING THE MAXIMUM TEMPERATURE
STOP
ADJUSTING THE MAXIMUM
TEMPERATURE STOP
T00295
Fig.78
Fig.79