Heatiator NEVO4236I NEVO3630I Indoor Fireplace User Manual


 
Heatilator • Evolution • 4065-114 Rev. o • 11/1152
D. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to
disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
RC100 (optional)
RC200 (optional)
Valve
Power supply
plugged into
junction box
Module
Pilot
assembly
Wiring
harness
Battery
holder
RED
RED
RED
RED
BRN
BLK
BLK
ORG
GRN
ORG
WHT
Wall
switch
wires
BLK
RED
WHT
RC300 (optional)
Figure 13.1 IntelliFire Plus Intermittent Pilot Ignition (IPI) Wiring Diagram
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.