Heatiator NEVO4236I NEVO3630I Indoor Fireplace User Manual


 
Heatilator • Evolution • 4065-114 Rev. o • 11/1120
D
Clearance to Ceiling
30 in. (762 mm)
0 in.
0 in. TO LEVEL
OF STANDOFFS
Combustible Object
36 in.
(914 mm)
0 in.
Combustible flooring may be installed next
to the front of the appliance.
Drywall
1/2 in.
(13 mm)
1/2 in.
(13 mm)
C
A
B
Figure 5.2 Clearances to Combustibles
C. Clearances
NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly on
carpeting, vinyl, tile or any combustible material other than
wood.
WARNING! Risk of Fire! Maintain speci ed air space
clearances to appliance and vent pipe:
Note: If the inside of the framed cavity is to be
nished, the framing dimensions must include the
nished surface. If drywall is to be attached to the
rear wall, the depth must be measured from the
drywall surface.
Insulation and other materials must be secured to
prevent accidental contact.
The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with replace or chimney.
Failure to maintain airspace may cause overheating and
a re.
Model
A
Rough Opening
(Width)
B
Rough Opening
(Height)
C
Rough Opening
(Depth)
D
Rough Opening
(DVP Pipe)
D
Rough Opening
(SLP Pipe)
in. mm in. mm in. mm in. mm in. mm
NEVO3630 36 914 39 7/8 1013 19 5/8 498 10 254 9 229
NEVO4236 42 1067 39 7/8 1013 19 5/8 498 10 254 9 229
If using the optional nishing trim, the unit must be installed on a platform at least 1 1/2 in.
high. The rough opening height must be increased the same amount as the height of the
platform.