Heatiator IDV4833IT Indoor Fireplace User Manual


 
Heatilator • ICON DV-IDV Series • 4042-575 • Rev. S • 5/11 45
A. Remove Shipping Materials
Remove shipping materials from inside or underneath the
rebox.
Front refractory (three pieces) package shipped in front
of glass.
Lower decorative front face, left and right refractory
shields shipped on top of front refractory box.
Remove ember material package shipped inside the
column.
15
15
Appliance Setup
F. Heat-Zone
®
Gas
Install the Heat-Zone
®
Gas Kit before enclosing the appli-
ance.
Remove one of two square cover plates for each kit from
the top of the appliance. Set the screws aside, discard
the cover plate.
Cover Plates
Replace the cover plate with the heat zone collar from
the kit. Use the three screws removed from the cover
plate.
Return to Heat-Zone
®
Gas instructions.
G. Refractory
All refractory internal to the rebox comes pre-installed.
See Section 15.L. for installation of bottom front and side
refractories.
B. Remove Fixed Glass Assembly
See Section 15.J.
C. Remove Materials Shipped Inside Firebox
Three top logs are shipped inside the rebox.
D. Clean the Appliance
Clean/vacuum any sawdust that may have accumulated
inside the rebox or underneath in the control cavity.
E. Accessories
Install approved accessories per instructions included
with accessories. Contact your dealer for a list of ap-
proved accessories.
WARNING! Risk of Fire and Electric Shock! Use ONLY
Hearth & Home Technologies-approved optional acces-
sories with this appliance. Using non-listed accessories
could result in a safety hazard and will void the warranty.